Company Logo

MAIN FIRE STATION OCCURRENCE REPORT

Shift Shift Cycle Date Emergency Drill
BRAVO MFS Night December 13, 2025 63 49

Shift Manning

Name Vehicle
SFM Suhaimi Bin Kassiron RIV2
FM Mohd Fakhrullah Bin Mohd Hatta RIV2
Muhammad Salihin bin Marasip MRV1
Mohd Irwan Syah Bin Rohaizan CREW MRV1
Ahmad Tarmisham Bin Othman FT1
Fathul Imran Bin Dol Malek FT2
Mohd Lutman Hakim Bin Harun FT3
Muhammad Syamil Bin Samad FT4
Mohammad Ain Nur-Muslim Bin Tarli HZ1
Khairul Hafiz Bin Eddy Arifin CREW HZ1
Muhammad Arief Izzuddin Bin Shokry TTL
Muhammad Iszuan Bin Suhadi PM1
Mohd Khairihizmi bin Ibrahim -

Staff On Leave

Name Leave Type
FM Mohammad Adib Syahmi Bin Amri Sick Leave
Mohd Hazeem Bin Abdul Halim Annual Leave

Occurrence Book Entry

Time Remarks
17:00

RO 32064 TERIMA TUGAS DARIPADA RO CHARLIE DALAM KEADAAN BAIK DAN TERKAWAL.

18:48

STAREX DIPANDU FF ISZUAN BERSAMA FF MUSLIM KE SG RENGIT URUSAN KEBAJIKAN.

19:43

STAREX SAMPAI DI BALAI.

20:05

OCC LAPOR KEKUATAN ANGGOTA KEPADA RSM, USM DAN CSM DITERIMA BAIK.

20:15

ANGGOTA MEMBUAT UJIAN WALKIE TALKIE.

20:20

ANGGOTA MEMBUAT PEMERIKSAAN KE ATAS JENTERA DAN PERALATAN.

21:21

OCC RECEIVED A CALL FROM USM AIZAD FALIQ VIA DTRS (COMMON EMERGENCY) INFORMING OF A HAZMAT DRILL AT RWTP (CHLORINE BUILDING), SCENARIO: CHLORINE LEAK.

21:22

OCC ACTIVATED CEFS TEAM MFS, MEDIC BRAVO, AND PSCC TO THE LOCATION.

21:23

MARSHALL 1 REPORTED 8 EMERGENCY VEHICLES WITH 12 PERSONNEL DEPLOYED TO THE LOCATION. OCC NOTIFY MARSHALL 1 WIND DIRECTION AND WINDSPEED.

21:26

MARSHALL 1 ARRIVED AT THE LOCATION AND COMMENCED INCIDENT SIZE-UP.

21:28

MARSHALL 1 CONFIRMED EMERGENCY DRILL SCENARIO: CHLORINE LEAK AT CHLORINE BUILDING.

21:30

MARSHALL 1 REPORTED CEFS TEAM SET UP ONE GROUND MONITOR LINE.

21:33

MEDIC 03 ARRIVED AT THE LOCATION.

21:35

MARSHALL 1 REPORTED TWO CEFS PERSONNEL ENTERED THE SCENE FOR GAS CHECK.

21:37

MARSHALL 1 REPORTED GAS READING: 0% LEL.

21:40

MARSHALL 1 REPORTED TWO CEFS PERSONNEL AND ONE ERT ENTERED THE SCENE TO CONFINE THE LEAK.

21:43

MARSHALL 1 REPORTED TUBING LEAK SUCCESSFULLY ISOLATED.

21:46

MARSHALL 1 REPORTED OVERHAUL CONDUCTED AT THE SCENE. READINGS NORMAL: O₂ (20.9%) AND LEL (0%).

21:47

ON-SCENE COMMANDER DECLARED OPERATION STAND DOWN.

22:02

MARSHALL 1 REPORTED ALL EMERGENCY VEHICLES RETURNED TO THE FIRE STATION.

22:06

MARSHALL 1 REPORTED ALL EMERGENCY VEHICLES AND PERSONNEL SAFELY ARRIVED AT THE MAIN FIRE STATION.

22:10

ANGGOTA HADIR AKTIVITI POSTMORTEM DRILL.

23:40

OCC RECEIVED A CALL FROM RSM MAT KAMIS VIA DTRS (COMMON EMERGENCY) INFORMING OF A HAZMAT DRILL AT LTU UNIT 1320 (PUMP 002), SCENARIO CAUSTIC LEAK.

23:41

OCC ACTIVATED CEFS TEAM MFS, MEDIC BRAVO, AND PSCC TO THE LOCATION.

23:42

MARSHALL 1 REPORTED 8 EMERGENCY VEHICLES WITH 12 PERSONNEL DEPLOYED TO THE LOCATION. OCC NOTIFIED MARSHALL 1 OF WIND DIRECTION AND WIND SPEED.

23:48

MARSHALL 1 REPORTED ARRIVAL AT LOCATION AND COMMENCED SIZE-UP OF THE INCIDENT AREA.

23:49

MARSHALL 1 CONFIRMED AN EMERGENCY DRILL IN PROGRESS, SCENARIO CAUSTIC LEAK AT PUMP 002.

23:51

MEDIC 03 ARRIVED AT LOCATION.

00:03

MARSHALL 1 REPORTED 2 CEFS PERSONNEL AND 1 ERT MEMBER ENTERED THE SCENE TO CONTAIN THE LEAK.

00:05

MARSHALL 1 REPORTED THE LEAK WAS ISOLATED AND THE SPILL CONTAINED USING ABSORBENT PADS.

00:08

MARSHALL 1 REPORTED DIVER TEAM COMMENCED DECONTAMINATION.

00:14

MARSHALL 1 REPORTED DIVER TEAM COMPLETED DECONTAMINATION.

00:16

MARSHALL 1 REPORTED OVERHAUL IN PROGRESS AT SCENE. ATMOSPHERIC READINGS NORMAL: O₂ (20.9%) AND LEL (0%).

00:17

ON-SCENE COMMANDER DECLARED OPERATION STAND DOWN.

00:30

MARSHALL 1 REPORTED ALL EMERGENCY VEHICLES BACK TO FIRE STATION.

00:35

MARSHALL 1 REPORTED ALL EMERGENCY VEHICLES AND PERSONNEL SAFELY ARRIVED AT MAIN FIRE STATION.

00:40

ANGGOTA HADIR AKTIVITI POSTMORTEM DRILL

04:00

ANGGOTA MELAKUKAN AKTIVITI PEMBERSIHAN JENTERA.

07:00

ANGGOTA MELAKUKAN AKTIVITI KEBERSIHAN BALAI.

07:30

ANGGOTA MELAKUKAN PENYERAHAN TUGAS JENTERA DAN BALAI.

08:00

RO 32064 SERAH TUGAS OCC KEPADA RO PASUKAN CHARLIE DALAM KEADAAN BAIK DAN TERKAWAL.

Verification

Check by : Mohd Khairihizmi bin Ibrahim Verify by : SFM Suhaimi Bin Kassiron
hizmi